The deadman is on the 30 pin molex connector labeled P7. Device ignition to forklift ignition circuit (on a 10 pin molex labeled P6, wire 37-1).Device battery (-) negative to forklift battery (-) negative on a 6 pin Molex labeled P12, wire 13-1.Device battery+ to forklift battery+ (on a 6 pin molex labeled P12, wire 40-1).Locate the control board and connect the device as follows (see images below):.The connections are located to the right of the driver's position at the control board. The install type chosen during validation must reflect the deadman’s polarity. It is not necessary to connect a relay to the deadman. Connect the device’s input 1 (blue wire) to the deadman connection wire using a heat shrink butt connector and inline fuse.